Transport Package: | Box |
---|---|
Trademark: | FarmaMed |
Origin: | Jiangsu |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Constant pressure residual chlorine detection module includes pH electrode,residual chlorine electrode(platinumelectrode,titanium
electrode),installation backplane,flow meter and controller.
Features:
-Exclusive for running water testing
-Self-cleaning function
-Safe water&Environment protection
-Easy to maintain
Test Item | Residual chlorine, pH, temperature, flow rate |
Measuring range | Residual chlorine: 0-3mg/L |
pH: 0-14 | |
Temperature: 0-60ºC | |
Flow rate: 16-40L/H | |
Accuracy | Residual chlorine: 0.01-0.2:±0.02mg/L; 0.21-3.00mg/L; ±0.1mg/L or 5%, whichever is greater |
pH: ±0.1 | |
Temperature: 0.1ºC | |
Flow rate: 1L/H | |
Resolution | Residual chlorine: 0.01mg/L |
Current: 0.01μA | |
pH: 0.01 | |
Temperature: 0.1ºC | |
Flow rate: 1L/H | |
Temperature element | NTC 10K |
Flow rate requirement | 16-40L/H, 20L/H optimal |
Power | 0.5W |
Power supply | 12-24V DC, standard 5m shielded cable, length OEM available |
Data output | RS-485 MODBUS-RTU protocol |
IP grade | BNC and flow meter interface: IP65; Other interfaces and structural parts: IP68 |
Main material | PMMA/PC/PTFE/glass/titanium/platinum/304 stainless steel/silicone O-ring |
Installation | Backplane installation |